HA-BVD Double Door Pulse Vacuum Autoclave.1

More Views

  • HA-BVD Double Door Pulse Vacuum Autoclave.1
  • HA-BVD Double Door Pulse Vacuum Autoclave.2
  • HA-BVD Double Door Pulse Vacuum Autoclave.3
  • HA-BVD Double Door Pulse Vacuum Autoclave.4

Double Door Pulse Vacuum Autoclave, Steam Sterilizer HA-BVD

Quick Overview

Double Door Pulse Vacuum Autoclave, Steam Sterilizer HA-BVD


Model: HA-BVD250, HA-BVD360, HA-BVD600, HA-BVD800, HA-BVD1200, HA-BVD1500, HA-BVD2000


Available Volume: 250 liters, 360 liters, 600 liters, 800 liters, 1200 liters, 1500 liters, 2000liters.

 

Double Door Pulse Vacuum Autoclave, Steam Sterilizer HA-BVD Instructions and Principle:

 

The main body is with horizontal rectangle double layer structure, the inside chamber is made of SUS30408 or SUS31608 stainless steel, the outer layer is made of the brushed decorative sheet, and the there is motorized door or sliding door for choose, pneumatic sealing, and the double door interlocking are strictly in accordance with the GSSD required.

 

The control system: Adopt the Siemens PLC and Siemens touch screen.

 

The piping system: Adopt with the reliable Germany Burket or GEMU pneumatic angle type valve, water ring pump and 0.22µm high efficiency sterile medical grade filters, the pipe clamp adopts the quick connectors, the piping and the related spares are all according to the sanitation standard.

 

1. With Germany Simens PLC platform independent research and development, human-Machine Interaction, convenient for operation.

 

2. Software design and manufacture products in strict accordance with the technical requirements for the sterilization process.

 

3. The Operating authority is divided into three levels to the manager, the technologist, and the operators.

 

4. Program interlocked, by the program is running, the sealing door can not be open.

 

5. All the alarm and the technical figures can be recorded and print.

 

6. If the inner chamber is higher than the safety pressure, the door can not be open.

 

7. Perfect product safety protection measures, 4 level emergency treatment of abnormal state.


Double Door Pulse Vacuum Autoclave, Steam Sterilizer HA-BVD

The cabinet utilize the physical characteristics of the saturated steam, which would release large amounts of latent heat 

and humidity during condensation, and with a period of time to keep the objects at high temperature and moist condition, 

the main protein of the bacteria would be solidified so that the bacteria can be killed. The device is widely used in pharmaceutical, 

medical, scientific and other industries for the high temperature sterilization, cooling and drying process to the biological products, 

medical devices, sterile clothing, tools utensils, media and the other items.


Double Door Pulse Vacuum Autoclave, Steam Sterilizer HA-BVD Specifictions and User Manual from Autoclave Manufacturer:

MODEL HA-BVD250 HA-BVD360 HA-BVD600 HA-BVD800 HA-BVD1200 HA-BVD1500 HA-BVD2000
Capacity(L) 250 360 600 800 1200 1500 2000
Inner Chamber Dimension
(L*W*H mm)
800*600*600 1000*600*600 1200*610*910 1500*610*910 1500*680*1180 1900*680*1180 1700*1000*1200
Outer Dimension
(L*W*H mm)
1100*1300*1700 1300*1300*1700 1500*1350*1950 1800*1350*1950 1790*1450*1950 2190*1450*1950 2000*1850*2000
Steam Pressuer 
and the Consumption
0.4-0.8Mpa
15KG
0.4-0.8Mpa
20KG
0.4-0.8Mpa
30KG
0.4-0.8Mpa
40KG
0.4-0.8Mpa
48KG
0.4-0.8Mpa
55KG
0.4-0.8Mpa
65KG
Water Source Pressure
and the Consumption
0.15-0.3Mpa
35KG
0.15-0.3Mpa
40KG
0.15-0.3Mpa
45KG
0.15-0.3Mpa
50KG
0.15-0.3Mpa
55KG
0.15-0.3Mpa
60KG
0.15-0.3Mpa
65KG
Power 2-2.4KW 2-2.4KW 3-3.6KW 3KW 4KW 4KW 4.5KW
Net Weight(KG) 900 1000 1400 1600 1800 2000 2500
Design Pressure 0.25Mpa
Design Temperature 139℃

 

You may also be interested in the following product(s)

Double Door Autoclave Horizontal Steam Sterilizer HT-HZA - Bluestone

Double Door Autoclave Horizontal Steam Sterilizer HT-HZA - Bluestone

Horizontal Cylindrical Pressure Steam Sterilizer Autoclave HA-BC - Bluestone

Horizontal Cylindrical Pressure Steam Sterilizer Autoclave HA-BC - Bluestone

   

Use spaces to separate tags. Use single quotes (') for phrases.

  1. isaac@alternativeexports.com Review by Isaac Reano

    Hello,

    My name is Isaac Reano, territory manager for Alternative Exports, Inc. We are a company that serves as a purchasing division to many prominent corporations in Latin America and the Caribbean. I have a request for an 2000 liters autoclave that I am hoping you can help me. Here is a list of characteristics that we are looking to meet or exceed:

    Capacity 2 cubic meters
    Material SUS 304
    Coefficient of welding 0.7
    Ventilation diameter DN • 32-40 mm
    Connections diameter hot and cold DN 40-50 mm
    Drain pipe diameter 40-50 mm DN
    Exhaust valve diameter 25-50 mm DN
    Setting exit diameter DN 25-40 mm
    Design Pressure 0.35 MPA
    Pressure less than or equal to 0.16 MPA operation
    Maximum operating temperature 150 ° C
    Approximately 1,200 L Water consumption per cycle
    Air consumption approximately 3,000 L per cycle
    Water Pump
    Control Panel
    Pipes and zippers
    Safety Valves
    Sterilization Baskets and Carriers

    Would you please let me know if you can provide a wholesale/resale price. Please include lead time and specification sheet with quote.

    Thank you,

    Isaac Reano (Posted on 2/27/15)


Write Your Enquiry Details

You're enquiring: Double Door Pulse Vacuum Autoclave, Steam Sterilizer HA-BVD